Frequency Conversion Water Supply System Constant Pressure Full Automatic for High Rise Buildings

Frequency Conversion Water Supply System Constant Pressure Full Automatic for High Rise Buildings
Basic Properties
Place of Origin: China shannxi xian
Brand Name: QITONG
Trading Properties
Minimum Order Quantity: 1
Price: Price on request
Payment Terms: L/C,T/T,D/P
Product Summary
Frequency conversion constant pressure water supply system for high-rise buildings. Features intelligent PLC control, automatic pressure adjustment, and energy savings up to 60%. Customizable flow (2-300m³/h) and pressure (0.2-1.6MPa). Includes safety protections and compact integrated design. OEM/ODM/OBM available.
Product Custom Attributes
Highlight

Frequency Conversion Water Supply System

,

High Rise Building Supply System

,

304 Stainless Steel Pump System

Capacity:
Variable (e.g., 1000 Liters/hour)
Driving Type:
Motor
Controlsystem:
PLC/Analog/Digital
Customized:
OEM, ODM, OBM
Pressure:
Low Pressure
Core Components:
Pressure Vessel, Pump, Motor, PLC
Specification:
Customized
Cable:
Customized
Machinery Test Report:
Provided
Material:
Stainless Steel/Plastic/Composite
Product Function:
Supply Clean And Safe Water
Advantage:
High Performance
Model:
W3.0/0.35-1.6-WY
Function:
High Efficiency Low Cost
Horsepower:
Customized
Product Description
Detailed Specifications & Features
Frequency Conversion Constant Pressure Water Supply System For High-rise Buildings

This complete integrated water supply solution is specifically designed for high-rise residential buildings, commercial complexes, office towers, and communities, addressing common water pressure instability issues.

Product Overview

Traditional water supply systems often suffer from unstable pressure: low pressure on high floors during peak usage and excessive pressure on lower floors, leading to small water flow, pipeline leakage, and reduced service life of terminal sanitary ware.

Equipped with intelligent frequency conversion control cabinet, stable water pump set, and pressure sensing module, this system automatically adjusts pump operating speed according to real-time water consumption to maintain constant pipeline pressure 24/7. It effectively saves energy, reduces water hammer impact, and enables unattended automatic operation.

Working Principle

Pressure sensors monitor real-time pipeline water pressure and transmit data to the PLC frequency conversion controller. When water consumption increases and pressure drops, the system increases pump frequency and rotating speed to boost water output. When water usage decreases and pressure rises, it reduces frequency to lower pump power.

The system dynamically matches water supply volume with actual demand, maintaining pipeline pressure within a preset stable range. It also supports sleep mode during low water consumption periods to reduce power consumption, with automatic switching between main and standby pumps for uninterrupted water supply.

Core Advantages
  • Constant Stable Water Pressure: Solves high-rise water shortage and low-flow issues, delivering balanced water pressure to all floors without manual adjustment
  • Remarkable Energy-Saving Performance: Frequency conversion adjusts power based on actual water demand, saving 30%-60% electricity compared to traditional constant-speed pump units
  • Full Automatic Intelligent Operation: Auto start-stop, pump alternate operation, fault alarm, and overload protection with no full-time staff required
  • Low Pipeline Damage & Long Service Life: Slow speed start-up reduces water hammer impact, preventing pipeline cracking, leakage, and valve damage
  • Complete Safety Protection: Overvoltage, undervoltage, overload, dry-run, phase loss, and leakage protection to prevent equipment failure
  • Compact Integrated Structure: All components assembled as a complete unit for easy transportation and quick on-site installation without complex civil works
  • Customized Configuration: Matches different building heights, resident quantities, and water consumption requirements with adjustable flow and pressure range
Technical Parameters
Parameter Specification
Applicable Scene High-rise residential buildings, office buildings, shopping malls, residential districts
Single Set Flow Range 2-300m³/h customizable
Constant Pressure Range 0.2-1.6MPa adjustable
Control Mode PLC + frequency converter automatic control
Pump Material 304 stainless steel water contact parts
Power Supply 380V/50Hz
Operation Mode Main & standby pump automatic switching
Protection Features Dry run, overload, overvoltage, phase loss, leakage protection
Application Scenarios
  • High-rise residential apartment buildings and villa communities
  • Commercial office buildings, shopping centers, and hotels
  • Factory staff dormitory areas and campus high-rise dormitories
  • New urban real estate supporting water supply projects
  • Reconstruction of old high-rise buildings with insufficient water pressure
Packaging & After-sales

Export fumigated wooden case packaging with complete installation drawings and operation tutorials. Core pumps, frequency converters, and controllers enjoy 1-year warranty. We provide personalized pressure and flow configuration design based on building height and user quantity, plus remote online technical guidance for global engineering contractors.

Related Products